絕緣電阻試驗儀
TOS7200

 TOS7200輸出電壓可選擇設置在-25至-1000 Vdc的範圍內,分辨率為1 V.由於配有窗口比較器和定時器功能,測試儀能夠根據各種安全標準有效地進行絕緣電阻測試。 此外,該產品還配備了面板存儲器作為標準功能,可通過遙控器,SIGNAL I / O連接器和RS-232C接口調用,便於自動測試系統構建。


  • 產品特性

    輸出電壓設定範圍:-25V ~ -1000Vdc (符合JIS C 1302-1994的輸出特性) 電阻測量範圍:0.01MΩ ~ 5000MΩ 搭載放電功能 搭載有視窗比較器 測量值保持功能 (在PASS期間保持試驗結束時的測量電阻值) 搭載有計時器功能 後部輸出端子 測量值監控端子 面板搭載有記憶體 (10種) 搭載有SIGNAL I/O、遙控器端子 標準安裝有RS-232C介面
  • 電壓電流

    輸出電壓設定範圍:-25V~-1000V、電阻測量範圍:0.01~5000M Ω 、搭載有SIGNAL I/O、遙控器端子、標準安裝有RS-232C接口

詳細規格

Output section

Output voltage range   -25 V to -1000 V
Resolution 1V
Setting accuracy ±(1.5% of setting + 2V)
Max. rated load 1W(−1000Vdc/1mA)
Max. rated current 1mA
Output terminal Output type Floating
Isolation voltage ±1000 VDC
Ripple 1 kV no load 2 Vp-p or less
Max. rated load 10 Vp-p or less
Short-circuit current 12 mA or less
Output rise time 50 ms or less (10 % to 90 %) [no load]
Discharge feature Forced discharge at the end of test (discharge resistance: 25 kΩ)

Voltmeter

Measurement range 0 V to -1200 V
Resolution 1V
Accuracy ±(1% of reading + 1V)

Resistance meter

Measurement range 0.01 MΩ to 5000 MΩ (In the range of over 100 nA to a maximum rated current of 1 mA)
Display R < 10.0 MΩ:□.□□MΩ
10.0MΩ≦ R < 100.0MΩ:□□.□MΩ
100.0MΩ ≦ R < 1000MΩ:□□□MΩ
1000MΩ ≦ R ≦ 5000MΩ:□□□□MΩ
R = measured insulation resistance
Accuracy 100nA < i ≦ 200nA:±(10% of reading)
200nA < i ≦ 1μA:±(5% of reading)
1μA < i ≦1mA:±(2% of reading)
[In the humidity range of 20 %rh to 70 %rh (no condensation), with no disturbance such as swinging of the test leadwire]
i =measured output-voltage value/measured resistance value
Measurement range   The current measurement range is selectable between AUTO and FIX.
AUTO Automatically changes the current measurement range according to the measured current value.
FIX Fixes the current measurement range based on the output voltage set value and LOWER set value (in UPPER OFF status).
Holding function The resistance measured at the end of test is held during the PASS interval

Judgment feature

Judgment method and judgment operation
Judgment Judgment method Display Buzzer SIGNAL I/O
UPPER FAIL If a resistance value equal or higher than the upper resistance is detected, the tester shuts off the output and returns an UPPER FAIL judgment. FAIL LED lights.
UPPER LED lights.
ON Outputs an U FAIL signal
LOWER FAIL If a resistance value equal or less than the lower resistance is detected, the tester shuts off the output and returns a LOWER FAIL judgment. Note that no judgment is made within the judgment wait time (WAIT TIME) after the start of the test. FAIL LED lights.
LOWER LED lights.
ON Outputs a L FAIL signal
PASS If no abnormality is found when the set test time has elapsed, the tester shuts off the output and returns a PASS judgment. PASS LED lights. ON Outputs a PASS signal
 
· A PASS signal is output for approx. 200 ms. However, if the PASS HOLD function is set to “HOLD,” the signal is continuously output until a STOP signal is input.
· An UPPER FAIL or LOWER FAIL signal is continuously output until a STOP signal is input.
· The FAIL and PASS buzzer volumes are adjustable. However, they cannot be adjusted individually, as they are set in common.
Setting range for the upper reference value (UPPER) 0.01 MΩ to 5000 MΩ [In the range of the maximum rated current or less]
Setting range for the lower reference value (LOWER) 0.01 MΩ to 5000 MΩ [In the range of the maximum rated current or less]
Judgment accuracy
For both UPPER and LOWER
Judgement current = test voltage /(UPPER,LOWER) 100nA ≦ i ≦ 200 nA 200 nA < i ≦ 1μA 1μA < i ≦ 1mA
UPPER、LOWER 0.01 ≦ R < 10.0MΩ − − ±(2% of setting + 3digit)
10.0 ≦ R < 50.0MΩ − ±(5% of setting + 5digit) ±(2% of setting + 3digit)
50.0 ≦ R < 100MΩ − ±(5% of setting + 5digit) ±(2% of setting + 3digit)
100 MΩ ≦ R < 200MΩ ±(10% of setting + 5digit) ±(5% of setting + 5digit) ±(2% of setting + 3digit)
200 MΩ ≦ R < 500MΩ ±(10% of setting + 5digit) ±(5% of setting + 5digit) ±(2% of setting + 3digit)
500 MΩ ≦ R < 1000MΩ ±(10% of setting + 5digit) ±(5% of setting + 5digit) ±(2% of setting + 3digit)
1000MΩ ≦ R < 2000MΩ ±(10% of setting + 50digit) ±(5% of setting + 50digit) −
2000MΩ ≦ R < 5000MΩ ±(10% of setting + 100digit) ±(5% of setting + 50digit) −
 
[In the humidity range of 20 %rh to 70 %rh (no condensation), with no disturbance such as swinging of the test leadwire]
The lower judgment requires a test duration of 0.5 s or more after the wait time has expired. It also requires a wait time of 1.0 s or more for a lower judgment of 200 nA or less.]
 

Input voltage range

Nominal voltage range (allowable voltage range) 100 V to 240 V AC (85 V to 250 V AC)
Power consumption at rated load 30 VA maximum
Allowable frequency range 47 Hz to 63 Hz
Insulation resistance 30 MΩ or more (500 V DC) [AC LINE to chassis]
Withstanding voltage 1390 V AC for 2 seconds, 10 mA or less [AC LINE to chassis]
Earth continuity 25 A AC / 0.1 Ω or less
 
*實際規格依型號與選配項目而異,詳情請洽啟宸科技。